Download Print deze pagina

Hilti TE 500-A36 Originele Handleiding pagina 26

Generatie 04
Verberg thumbnails Zie ook voor TE 500-A36:

Advertenties

Battery
Battery operating voltage
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
Operation
Preparations at the workplace
Switch the product off or remove the battery before making adjustments or changing acces-
sories.
Observe the safety instructions and warnings in this documentation and on the product.
Inserting the battery
WARNING
Risk of injury by short circuit or falling battery!
Before inserting the battery, make sure that the contacts on the battery and the contacts on the
product are free of foreign matter.
Make sure that the battery always engages correctly.
1.Charge the battery fully before using it for the first time.
2.Push the battery into the product until it engages with an audible click.
3.Check that the battery is seated securely.
Removing the battery
1.Press the battery release buttons.
2.Remove the battery from the tool.
Charging the battery
1.Before charging the battery, read the operating instructions for the charger.
2.Make sure that the contacts on the battery and the contacts on the charger are clean and dry.
3.Use an approved charger to charge the battery.
Fitting the side handle
CAUTION
Risk of injury! Loss of control over the breaker.
Check that the side handle is fitted correctly and tightened securely.
1.Switch off the power tool.
2.Release the side handle clamping band by turning the handle grip.
3.Slide the side handle clamping band over the chuck from the front and into the recess provided.
4.Set the side handle to the desired position.
5.Tighten the side handle clamping band by turning the handle grip.
Setting the power level
After the battery is inserted, the product is always set by default to full power.
1.Press the "button for half power". The product runs at half power.
The "half power indicator" lights up.
2.Press the "button for half power" again. The product runs at full power.
The "half power indicator" goes out.
21
2
36 V
−17 ℃ ... 60 ℃
−20 ℃ ... 40 ℃
−10 ℃ ... 45 ℃
19
2240495
*2240495*

Advertenties

loading