1.Check Generator,steam nozzle,spare parts and piping joints regularly in case of
water leakage and machine damage.
2.Its important to rinse and discharge deposits in water tank .This work should be
daily done or frequently done according to the local water quality and steam usage
frequency.
3.Be careful about over-heating at any circumstance.Check the firmness of all
electric joints.
B.Repair
1.replace heating elements: Shut off power,discharge the water out from water
tank,take off the top cover and heating elements cover,mark the places where the
wires are connected,remove the wire,and take heating elements out. Wear a gum
ring around the joints of heating elements,eliminate water fur from water thank,and
properly place new heating elements and tighten them.(Press the gum ring tightly
without turning it out from inside)
2.connect wires again,check the joints in case of water leakage,and place all
covers back.
3.replace circuit: Shut off power and water,remove the front cover,and mark the
place of water level probe.Remove the wires from the probe and circuit, place a
new probe,and screw it to the normal position. Connect the wire to the probe.
Caution:
Shut off power switches before maintenance and repair.
Normally operate the machine once after maintenance and repair as a test.
10