Stoomgenerator
4.Steam Nozzle should be installed inside Room.Connect decorative cover to
steam pipe joint,seal it with gel and screw steam nozzle on.Control the strength
properly in case of destroying the decorative cover and nozzle.The outlet of nozzle
must be downwards.
Caution:
A.If Generator is installed where it is hard for users to arrive,the water supplying
valve should be installed where it is easy to arrive in emergency.
B.The pressure magnetic valve can stand is 1 kg/cm².If the water pressure is too
high,turn the water supplying valve down or install a pressure reducing valve in
water supplying pipe.
C.Saddle valve or needle-shape valve is not suitable to be in drainpipe.
Completely dredge and rinse the pipe before connection.
D.Don't install Generator outdoors but vertically install it where it's easy for
maintenance service with arrows pointing up.
E.The piping system must be of copper pipes.Otherwise,it may damage the
machine. All joints/gap must be completely sealed in case of machine's damage by
leaking steam.If the hot water in water tank goes into Steam Room,it may cause
human burn or Room damage.Please install some proper protective devices
according to practical situation.
4.0 Installation of Steam Generator's Circuitry
Power Installation of Steam Generator
1. Make sure of proper voltage Refer to the nameplate of machine or Form 1.
2. Fuse or breaker must be installed according to Form 3.Some relative protective
devices against electricity leakage are also needed.
3. Use the wire with proper model by the local requirement.If necessary,install a
socket bear Steam Generator.The plug and socket must match.(Refer to the
Specific instruction) After sealing the gap/hole in the wall, connect Generator and
Control Panel with wire.
4. Plug the power wire and connection cable to Control Panel into matching
sockets in Generator.After fixing Generator's cover and Control Panel,turn
Generator's Power switch on.Turn Control Panel's switch on.Now the machine
starts working.
8