Download Print deze pagina

Optional Extras; Operational Problems - Troubleshooting - Jotul I 520 Installatiehandleiding En Gebruiksaanwijzing

Advertenties

Beschikbare talen

Beschikbare talen

Fig. 51
3. Turn one corner towards you and pull the inner bottom out.
4. When refi tting, follow the same procedure in reverse order.
7.3 Self-closing door
By making this change, you make the door self-closing.
Fig. 52
3
1
1
2
1. Loosen the two Allen screws.
2. Tighten the screw on the underside.
3. Tighten the Allen screw again.
NB! This operation must be preformed several times to
achieve the desired eff ect.
A
3

8.0 Optional extras

8.1 Leg Rack, complete
Item no. 51044759
8.2. Door lock, complete, left
For right-hinged door
Item no. 50045754
8.3 Frames
Frame for the Jøtul I 520 F
Item no. 50045750
Frame for the Jøtul I 520 FL/FR
Item no. 50045751
Frame for the Jøtul I 520 FRL
Item no. 50045752
8.4 Convection top plate, complete I
520 F
Item no. 50045755
8.5 Sheet metal grid
Sheet metal grid Jøtul I 520 F / FR / FL
Item no. 50051746
9.0 Operational problems
- troubleshooting
Poor draught
Check the length of the chimney and that it complies with
national laws and regulations. (See also «2.0 Technical
data» ). Make sure that the minimum cross section on
the chimney is according to «2.0 Technical data» in the
installation manual.
Make sure that there is not anything preventing the smoke
gasses from escaping: branches, trees, etc.
Upon suspicion of excessive/poor draught in the chimney,
seek professional help for measurement and adjustment.
The fi re extinguishes after a while
Make sure that the fi rewood is suffi ciently dry.
Find out whether there is negative pressure in the
house, close mechanical fans and open a window close
to the fi replace.
Check that the air vent is open.
Check that the fl ue outlet is not clogged by soot.