Check the accessories used for completeness and damage. Replace them if the damage is
considerable.
Check the operation of the connection system for the accessories. If it is in poor condition, have it
repaired by the Holmatro dealer.
6.4.2
Shut down
Retract the plunger(s) and then open them ± 5 mm. The tool can be stored without pressure.
Stop the tool.
Remove the battery pack and put it on the battery charger.
It is also possible to charge the battery on the tool with the on-tool charge cable.
A battery pack can be put on the battery charger. It can also be connected via the on-tool charge
cable. If these two functions are used, the battery pack on the tool is charged first.
6.4.3
Storing the battery pack
NOTICE
When the battery pack is not in use, it is advised to keep the battery pack connected to the
battery charger (connected to a power source) at all times. When the battery pack is full, the
battery charger automatically switches on and off at regular intervals to keep the battery
level at 100%.
Store the battery pack in a dry and well-ventilated area. The maximum storage temperature of 40 °C
(104 °F) may not be exceeded.
Make sure the equipment can not fall over during transport.
6.4.4
Cleaning and storage
NOTICE
If the tool has been used under water, a Holmatro Certified Technician must clean the tool as
soon as possible. To make sure that the tool operates correctly, it must be cleaned in less
than 1 week.
After normal use
1. Clean the tool and any accessories before storage.
2. Dry the tool if it was used in wet conditions. Apply a thin coat of preservative oil to the external steel
parts.
3. Store the tool in a dry and well-ventilated area.
After immersion
If a Holmatro Certified Technician can not clean the tool within 1 week, do these temporary maintenance
steps that follow. The Holmatro Certified Technician must clean the tool subsequently.
1. Remove the battery pack. Flush the tool, battery pack and accessories with fresh, clean water.
2. If the tool has been used in muddy or dirty water, the covers must be removed to remove residual
dirt.
Refer to Fig. 12
i
Remove the screws (A, 8x) from the upper cover.
ii
Remove the upper cover (B). Do not disconnect wiring.
iii
Remove the crews (C, 6x) from the bottom covers.
iv
Remove the bottom covers (D, 2x).
3. Flush the inner parts with fresh clean water and remove residual dirt and contamination.
4. Lubricate all exposed steel parts with a rust inhibitor and moisture repellant.