5. Depress the trigger switch
nOTE: Depending on your tool, depressing the trigger
switch activates a worklight
immediate work surface. The worklight will automatically
turn off 20 seconds after the trigger switch is released.
Recommendations for Tool Operation
•
When drilling, always apply pressure in a straight line with
the bit, but do not push hard enough to stall the motor or
deflect the bit. A smooth even flow of material indicates the
proper drilling rate.
•
Your hammer can be used for dry diamond drilling into
masonry up to 100 mm. For diamond drilling above this
diameter in masonry and regular large diameter diamond
drilling in masonry and concrete, we advise the use of
a dedicated diamond core drill. Follow the core bit or
manufacturer's recommendations for using the accessory.
nOTE: Always use core bits with integral centre drill systems
and ensure the RPM (speed) of the hammer does not
exceed the maximum rated RPM of the diamond core.
-
Insert the centre drill into its holder in the centre of the
core bit.
-
Remove and unplug the machine.
Remove the centre drill from its holder.
-
-
Plug the machine in and insert the core bit into
the workpiece.
WARNING:
•
Do not use this tool to mix or pump easily combustible
or explosive fluids (benzine, alcohol, etc.).
•
Do not mix or stir inflammable liquids
labelled accordingly.
MAINTENANCE
Your D
WALT power tool has been designed to operate
e
over a long period of time with a minimum of maintenance.
Continuous satisfactory operation depends upon proper tool
care and regular cleaning.
WARNING: To reduce the risk of serious personal
injury, turn tool off and disconnect battery pack
before making any adjustments or removing/
installing attachments or accessories. An accidental
start-up can cause injury.
The charger and battery pack are not serviceable.
Lubrication
Your power tool requires no additional lubrication.
Cleaning
WARNING: Electrical shock and mechanical hazard.
Disconnect the electrical appliance from the power source
before cleaning.
WARNING: To ensure safe and efficient operation,
always keep the electrical appliance and the ventilation
slots clean.
WARNING: Never use solvents or other harsh chemicals
for cleaning the non-metallic parts of the tool. These
4
.
10
designed to illuminate the
chemicals may weaken the materials used in these parts.
Use a cloth dampened only with water and mild soap.
Never let any liquid get inside the tool; never immerse any
part of the tool into a liquid.
Ventilation slots can be cleaned using a dry, soft non‑metallic
brush and/or a suitable vacuum cleaner. Do not use water or
any cleaning solutions. Wear approved eye protection and an
approved dust mask.
Optional Accessories
WARNING: Since accessories, other than those offered
by D
WALT, have not been tested with this product, use
e
of such accessories with this tool could be hazardous.
To reduce the risk of injury, only D
accessories should be used with this product.
Various types of SDS‑max® drill bits and chisels are available as
an option. Accessories and attachments used must be regularly
lubricated around the SDS‑max® fitment.
Consult your dealer for further information on the compatibility
of appropriate accessories.
Protecting the Environment
Separate collection. Products and batteries marked
with this symbol must not be disposed of with normal
household waste.
Products and batteries contain materials that can
be recovered or recycled reducing the demand for raw
materials. Please recycle electrical products and batteries
according to local provisions. Further information is available at
www.2helpU.com.
Rechargeable Battery Pack
This long‑life battery pack must be recharged when it fails
to produce sufficient power on jobs which were easily done
before. At the end of its technical life, discard it with due care for
our environment:
•
Run the battery pack down completely, then remove it from
the tool.
•
Li‑Ion cells are recyclable. Take them to your dealer or a
local recycling station. The collected battery packs will be
recycled or disposed of properly.
EngLIsH
WALT recommended
e
35