(11)
1. Push the on / off switch
2. Disconnect the pump from the mains.
3. Open the consumer on the pressure side.
4. Remove the connected hoses on the pressure and suction side.
5. Unscrew drain bolt
(1)
.
6. Tilt the pump to the suction and pressure side until water is no longer
discharged from either side.
7. Store the pump in a dry, enclosed and frost-free place.
Disposal of the product:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household
waste. It must be disposed of in line with local environmental
regulations.
IMPORTANT!
v Dispose of the product through or via your municipal recycling collection
centre.
6. TROUBLESHOOTING
DANGER! Electric shock!
Risk of injury due to electric current.
v Disconnect the product from the mains before you
troubleshoot the product.
To troubleshoot with the error diagnosis system [ Fig. T1 ]:
The pump is equipped with an error diagnosis system which indicates
various error states via the error LED
1. Disconnect the pump from the mains.
2. Make the respective remedies from the table below.
3. Start the pump again.
The error display has been cleared and the pump is ready for operation
again.
Problem
Possible Cause
Error-LED flashes 1 time
The pump does not pump water for 30 seconds during the
(with a 2 second break)
initial operation.
Pump does not suck water
Pump was not sufficiently
filled with liquid to be pumped.
Air cannot escape on the pres
sure side, because the pressure
side outlets are closed.
Pump does not start
The pump housing has heated
up and the thermal circuit brea
ker has been activated.
The impeller is blocked.
Only for Art. 1758:
The flow sensor is dirty.
Flow sensor signal is faulty
Error-LED flashes
The pump does not pump water for 6 minutes during the
2 times (with a 2 second
initial operation.
break)
Pump does not suck water
Problem on the suction side.
Suction hose deformed or bent. v Use a new suction hose.
GAR_01757-20.960.12_2025-01-09.indd 11
GAR_01757-20.960.12_2025-01-09.indd 11
to position 0.
(e)
.
Remedy
v Fill the pump and make sure
that water does not drain out
on the pressure side during
the suctioning process
(see 3. OPERATION).
v Open the pressure side
outlets (see 3. OPERATION).
1. Open possible shutoff device
in the pressure line (release
pressure).
2. Ensure sufficient ventilation
and let the pump cool down
for 20 min.
1. Loosen the impeller (see
"To loosen the impeller").
2. Let the pump cool down for
20 min.
v Clean the flow sensor (see
"To clean the flow sensor").
v Immerse the suction hose
end under water.
v Eliminate any leak on the
suction side.
v Clean the check valve on
the suction line and check
the installation direction.
v Clean the suction filter on the
suction hose end.
v Clean the filter lid seal and
turn the lid until the stopper
(see 4. MAINTENANCE),
v Clean the filter in the pump.
Problem
Possible Cause
Pump does not start
The thermal circuit breaker
has been activated
(motor overheated).
Error-LED flashes
The pump does not pump water for 30 seconds during the
3 times (with a 2 second
current operation.
break)
Water supply disrupted
Problem on the suction side.
on the suction side
Suction hose deformed or bent. v Use a new suction hose.
Pump does not start
The thermal circuit breaker
has been activated
(motor overheated).
Only for Art. 1758:
The flow sensor is dirty.
Flow sensor signal is
faulty
Error-LED flashes
The pump switches off during on-going operation
4 times (with a 2 second
after 60 minutes.
break)
Leakage warning is
Leak on pressure side
activated
(e. g. dripping tap).
The maximum duration of the
leakage warning (low quantity
program 60 min. or 2 min.)
has been exceeded.
The check valve is blocked.
Only for Art. 1758:
The flow sensor is dirty.
Flow sensor signal is faulty
Error-LED is off
Pump does not start or stops suddenly during operation
Mains plug is disconnected.
Power failure.
RCD has triggered
(residual current).
Electrical interruption.
Error-LED is off
Pump frequently switches on and off without water retrieval.
Only for Art. 1757
Longer periods of nonuse.
(see fig. T4)
To loosen the impeller [ Fig. T2 ]:
If the impeller is stuck due to dirt, the Error LED flashes 1 time
(with a 2 second break).
(16)
1. Turn the motor shaft
with a screw driver.
This will loosen the blocked impeller.
2. Start the pump (see 3. OPERATION).
Only for Art. 1758: To clean the flow sensor [ Fig. T3 ]:
If the flow sensor is stuck due to dirt, the Error LED flashes
(with a 2 second break).
1. Loosen both screws
(17)
.
(18)
2. Remove the cover
.
3. Loosen the screw
(19)
and remove the clip
(21)
4. Loosen the cap
counterclockwise (e. g. with a screwdriver).
(22)
5. Remove and clean the impeller
Remedy
v Let the pump cool down
for 20 min.
v Immerse the suction hose
end under water.
v Eliminate any leak on the
suction side.
v Clean the check valve on
the suction line and check
the installation direction.
v Clean the suction filter on the
suction hose end.
v Clean the filter lid seal and
turn the lid until the stopper
(see 4. MAINTENANCE),
v Clean the filter in the pump.
v Let the pump cool down for
20 min.
v Clean the flow sensor (see
"To clean the flow sensor").
v Eliminate any leak on the
pressure side.
v When using the low quantity
programme, shorten the
watering duration or interrupt
for 5 minutes.
v Increase the water consump
tion.
v Clean the check valve (see
"To clean the check valve").
v Clean the flow sensor (see
"To clean the flow sensor").
v Connect the mains plug.
v Check the fuse and the
cables.
v Disconnect the pump
and contact the GARDENA
Service.
v Disconnect the pump
and contact the GARDENA
Service.
v Pull piston
at the check
!K
valve several times prior to
commissioning after longer
periods of nonuse.