Warning! Qualified Technician Required for
Service and Installation
Basic Installation and Configuration
Guidelines
Use minimum 6AWG copper conductors only. Torque field
connections between 21 and 23 in lbs.
Readily accessible disconnecting means to be provided at time of
instal- lation.
Permanently connected.
Connect only to a circuit protected by a Class A Ground Fault
Circuit Interrupter (GFCI) or Residual Current Device (RCD)
mounted at least 5' (1.52M) from the inside walls of the spa/hot
tub and in line of sight from the equipment compartment.
CSA enclosure: Type 2
Refer to Wiring Diagram inside the cover of the control enclosure.
Refer to Installation and Safety Instructions provided by the spa
manufac- turer.
Warning:
People with infectious diseases should not use a spa or
hot tub.
Warning:
To avoid injury, exercise care when entering or exiting
the spa or hot tub.
Warning:
Do not use a spa or hot tub immediately following
strenuous exercise
Warning:
Prolonged immersion in a spa or hot tub may be
injurious to your health
Warning:
Maintain water chemistry in accordance with the
Manufactur- ers instructions.
Warning:
The equipment and controls shall be located not less
than 1.5 meters horizontally from the spa or hot tub.
Warning! GFCI or RCD Protection.
The Owner should test and reset the GFCI or RCD on a regular
basis to verify its function.
Warning! Shock Hazard! No User
Serviceable Parts.
Do not attempt service of this control system. Contact your dealer
or service organization for assistance. Follow all owner's manual
power connection instructions. Installation must be performed by
a licensed electrician and all ground- ing connections must be
properly installed.
Gefabriceerd onder een of meer van deze patenten. V.S. patenten: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370,
6590188, 6976052, 6965815, 7030343, 7,417,834 b2, Canadees patent: 2342614, Australisch patent: 2373248 andere patenten zowel
buitenlands als binnelands aangevraagd en in afwachting. Alle materialen auteursrecht van Balboa Water Group.
CSA Compliance/Conformité
Caution:
Test the ground fault circuit interrupter or residual
current device before each use of the spa.
Read the instruction manual.
Adequate drainage must be provided if the equipment
is to be installed in a pit.
For use only within an enclosure rated CSA Enclosure 3.
Connect only to a circuit protected by a Class A ground
fault circuit interrupter or residual current device.
To ensure continued protection against shock hazard,
use only identical replacement parts when servicing.
Install a suitably rated suction guard to match the
maximum flow rate marked.
Warning:
Water temperature in excess of 38°C may be injurious
to your health.
Disconnect the electrical power before servicing.
Attention:
Toujours verifier l'efficacite du disjoncteur differentiel
avant d'utiliser differentiel avant d'utiliser le bain.
Lire la notice technique.
Lorsque l'appareillage est installe dans une fosse, on
doit assurer un drainage adequat.
Employer uniquement a l'interieur d'une cloture CSA
Enclosure 3.
Connecter uniquement a un circuit protege par un
disjoncteur differen- tiel de Class A.
Afin d'assurer une protection permanente contre le
danger de shock electrique, lors de l'entretien
employer seulement des pieces de rechange
identiques.
Les prises d'aspiration doivent etre equipees de grilles
convenant au debit maximal indique.
Avertissement:
Des temperatures de l'eau superieures a 38°C peuvent
presenter un danger pour la sante.
Deconnecter du circuit d'alimentation electrique
avante l'entretien. Warning/Advertissement:
Disconnect the electric power before servicing. Keep
access door closed.
Deconnecter du circuit d'alimentation electrique avant
l'entretien. Garder la porte fermer.
150