Spa Behavior
Pumps
Press the "Jets 1" button once to turn pump 1 on or off, and to shift between low- and high-speeds if equipped.
If left running, the pump will turn off after a time-out period. The pump 1 low-speed will time out after 30 minutes. The
high-speed will time out after 15 minutes.
On non-circ systems, the low-speed of pump 1 runs when the blower or any other pump is on. If the spa is in Ready
Mode (See page 6), Pump 1 low may also activate for at least 1 minute every 30 minutes to detect the spa
temperature (polling) and then to heat to the set temperature if needed. When the low-speed turns on automatically,
it cannot be deactivated from the panel, however the high speed may be started.
Circulation Pump Modes
If the system is equipped with a circ pump, it will be configured to work in one of three different ways:
1, The circ pump operates continuously (24 hours) with the exception of turning off for 30 minutes at a time when the
water temperature reaches 3°F (1.5°C) above the set temperature (most likely to happen in very hot climates).
2, The circ pump stays on continuously, regardless of water temperature.
3, A programmable circ pump will come on when the system is checking temperature (polling), during filter cycles,
during freeze conditions, or when another pump is on.
The specific Circulation Mode that is used has been determined by the Manufacturer and cannot be changed in the
field.
Filtration and Ozone
On non-circ systems, Pump 1 low and the ozone generator will run during filtration. On circ systems, the ozone will
run with the circ pump.
The system is factory-programmed with one filter cycle that will run in the evening (assuming the time-of-day is
properly set) when energy rates are often lower. The filter time and duration are programmable. (See page 10)
A second filter cycle can be enabled as needed.
At the start of each filter cycle, the blower (if there is one) or Pump 2 (if there is one) will run briefly to purge its
plumbing to maintain good water quality.
Freeze Protection
If the temperature sensors within the heater detect a low enough temperature, then the pump(s) and the blower
automatically activate to provide freeze protection. The pump(s) and blower will run either continuously or periodically
depending on conditions.
In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may
not be sensed by the standard sensors. Auxiliary freeze sensor protection acts similarly except with the temperature
thresholds determined by the switch. See your dealer for details.
Clean-up Cycle (optional)
When a pump or blower is turned on by a button press, a clean-up cycle begins 30 minutes after the pump or blower
is turned off or times out. The pump and the ozone generator will run for 30 minutes or more, depending on the
system. On some systems, you can change this setting. (See the Preferences section on page 12)