Daikin Tewis ECO2SMART Handleiding pagina 64

STORED APPLICATION PARAMETERS (TABLE 2.7)
LABEL
CP30_dOnStep_Asp
CP31_dOffStep_Asp
CP32_dOffOnInverter_Asp
CP33_dOnOnInverter_Asp
CP34_dOffOnCP1_Asp
CP35_dOnOnCP1_Asp
CP36_dOffOnCP2_Asp
CP37_dOnOnCP2_Asp
CP38_dOffOnCP3_Asp
CP39_dOnOnCP3_Asp
CP40_dOffOnCP4_Asp
CP41_dOnOnCP4_Asp
CP42_dOnStep_Inverter
CF01_TipoSondaTempReg
CF02_PesoMediaT2T3
CF03_SetMaxPresionP11
CF04_DifMaxPresionP11
CF07_DesfaseTiempoCpsHT
CF08_SetMinTempHX1
CF09_DifMinTempHX1
CF10_PesoMediaT4
CF11_PesoMediaT5
CF12_PesoMediaPorcEV1
CF13_PesoMediaP1
CF14_TipoSondaTempPorcCps
CF15_TonEV1Arranque
CF16_TipoArranqueCPs
CF17_TempMinimaSGCPC
CF18_DifTempMinimaSGCPC
CF19_PresMinimaSGCPC
CF20_DifPresMinimaSGCPC
CF21_TOffOnECO2
C/ Sir Alexander Fleming, 7 _ 46980 Paterna (Valencia) SPAIN info@tewis.com www.tewis.com (+34) 963 13 42 02
DESCRIPTION
CFG COMPRESSORS "TIMES"
Time between Step Up ECO2 Compressors
Time between Step Down ECO2 Compressors
Delay Off-On start-up Inverter Compressor
Delay On-On start-up Inverter Compressor
Delay Off-On start-up CP1
Delay On-On start-up CP1
Delay Off-On start-up CP2
Delay On-On start-up CP2
Delay Off-On start-up CP3
Delay On-On start-up CP3
Delay Off-On start-up CP4
Delay On-On start-up CP4
Delay in first start-up of the Inverter compressor
CFG CONFIGURATION
T2 or T3 regulation sensor type:
0 → T2 Sensor
1 → T3 Sensor
2 → T5
Weighted average weight T2-T3 sensors
Maximum P11 pressure to close EV1
Dif. reset Maximum P11 pressure to close EV1
ECO2 start-up time offset with respect to MT compressors
Set Minimum HX1 inlet temperature for ECO2 operation
Dif Minimum HX1 inlet temperature for ECO2 operation
Weighted average weight T4 sensor
Weighted average weight T5 sensor
Weighted average weight percentage EV1
Weighted average weight P1 sensor
Sensor type for percentage calculation
start-up of ECO2 compressors
0 → T2 Sensor
1 → T3 Sensor
EV1 start-up time offset after starting the MT
compressors
ECO2 CPs start-up calculation type:
0 → Only Temperatures Table
1 → Temps. Table + MT Comp. Percentage Calc.
Minimum gas-cooler output temperature to
enable the compressors in PC mode
Minimum gas-cooler outlet differential temperature to
disable the compressors in PC mode
Minimum SGC Pressure for PC system start-up
Differential deact. Minimum SGC pressure PC
Time between stop-start of the ECO2 system
DEFAULT
UM
LEVEL
VALUE
120
sec
1
180
Sec
1
120
Sec
1
180
Sec
1
240
Sec
1
360
Sec
1
240
Sec
1
360
Sec
1
240
Sec
1
360
Sec
1
240
Sec
1
360
Sec
1
1
Sec
1
0
Num
1
60
num
1
59.0
Bar
1
10
Bar
1
30
Sec
1
o C
5.0
1
o C
2.0
1
60
Num
1
60
Num
1
30
Num
1
30
num
1
0
Num
1
600
sec
1
1
Num
1
25.0
num
1
1.0
num
1
60.0
bar
1
1.0
bar
1
600
sec
1
20
loading

Deze handleiding is ook geschikt voor: