EN
• Follow all the safety precautions and instructions in this operating (and installation)
manual.
This operating manual must always be available on the site so it can be accessed by
qualified staff and the operator.
These operating instructions must be retained by the operator.
1.6 RISKS AND CONSEQUENCES OF NON-COMPLIANCE WITH THE OPERATING
MANUAL
Failure to comply with this operating and installation manual will result in the loss of
warranty rights and rights to damages.
2. TRANSPORT / TEMPORARY STORAGE / RETURN / DISPOSAL
2.1 RECEIVING INSPECTION
• When handling the goods, check the condition of the packaging of the pumping station delivered (tank, pumps and
control box according to the model chosen).
• In case of damage, note the exact damage and immediately notify the retailer in writing.
2.2 TRANSPORT
DANGER
Pumping station falling over.
Risk of injury if the pumping station falls!
• The pumping station must be transported in a vertical position.
• Observe the indicated weights.
• Never hang up the pump by the electric cable.
• Use a suitable means of transport.
• The pumping station has been inspected to make sure there is no damage due to transport.
• Choose suitable means of transport according to the weight table. See attached leaflet.
Weight of the tank:
Sanifos® 110
110 litre tank
Sanifos® 280
280 litre tank with hydraulics to be assembled
Sanifos® 610
610 litre tank with pre-assembled hydraulics and floats
Sanifos® 1300
1300 litre tank with pre-assembled hydraulics and floats
2.3 TEMPORARY STORAGE / PACKAGING
• Store in a cool, dark, dry and frost-free place.
In the case of commissioning after an extended storage period, take the following precautions for the installation of the
pumping station.
NOTICE
Damp, dirty or damaged holes and points.
Leakage or damage to the pumping station!
Clear the pumping station's blocked openings at the time of the installation.
2.4 RETURNS
• Properly drain the pumping station.
• Rinse and decontaminate the pumping station, especially if it has transported harmful, explosive, hot or otherwise dan-
gerous liquids.
2.5 DISPOSAL AT THE END OF LIFE
At the end of its life, this product must be returned to a dedicated collection point.
It cannot be treated as household waste.
Ask your local council about where to take the old appliance so that it can be recycled or destroyed.
3. DESCRIPTION
3.1
GENERAL DESCRIPTION
Sanifos® are pumping stations specially developed for private, commercial and small-scale use (small buildings, shops,
public places).
22
WEIGHT
10 kg
25 kg
1 pump
2 pumps
55 kg
67 kg
116 kg