lower than the start measurement, the device
will detect it as an open window and automati-
cally switch off.
1. Turn on the device (see 'Starting').
2. Select one of the two heating levels (see 'Heating
Level Setting').
Please note: The window test can only be carried
out when a heating level is selected, not in the fan
setting mode.
3. Press the window button
display
on the display starts to blink:
F
4. The first measuring cycle the window measurement
starts after 1 minute.
5. The first comparison measurement is carried out
after more 5 minutes. If the measured temperature
is more than 8°C below the start measurement, the
device turns off and the window check is comple-
ted. If this is not the case, the device will continue to
heat and the test will go on.
6. The second comparison measurement is made10
minutes after the start measurement. If the measured
temperature is more than 8°C below the start mea-
surement, the device turns off and the window check
is completed. If this is not the case, the second com-
parison measurement will be taken as a new start
measurement and the new measurement cycle will
start and run as described in steps 4 and 5.
7. As far as you do not finish the window test by
pressing the window button
and 5 until you see a temperature drop of 8°C
within a cycle.
As soon as the device detects an open window, it stops
to heat. An audible alarm will sound for 5 seconds and
the fan will run 30 seconds till the standby mode. The
temperature indicator
D
blinking on the display. While LED „OF" blinks, the swit-
ched-off device is at the "open-window" mode.
. The temperature
3
, repeat steps 4
3
and the LED „OF" are shown
Please note: When the window test is completed, the
device must be started manual, if desired. To do so,
press the on/off button
1
turn the device off. The heater switches off. The blinking
temperature indicator
F
tor „OF" will be deleted.
THERMAL OVERLOAD PROTECTION / SAFETY
SHUT-DOWN
If the measured room temperature 51°C, the device swit-
ches off automatically. The fan runs 30 seconds before it
turns off. A countdown is shown on the display.

FAN MODE

To use the ceramic wall heater as a fan only, proceed
as follows:
On the control panel:
In Standby mode, press the ON/OFF button
The unit is now in fan mode.
Using the remote control:
In Standby mode, press the ON/OFF button
The unit is now in fan mode.
M aintenance, Cleaning and
Storage
Always disconnect the power plug when the device
is not in use and before any cleaning or in the
event of operating faults!
Clean the device only when it is turned OFF and
in a cooled condition.
Ensure that no moisture penetrates into the device
in order to avoid irreparable damage.
Clean the housing with a damp soft cloth only.
Do not use aggressive and/or abrasive cleaning
agents.
on the remote control unit to
on the display and the indica-
once.
E
once.