3.
PUMPED FLUIDS
The machine has been designed and built for pumping water, free from explosive
substances and solid particles or fibres, with a density of 1000 kg/m³ and a
kinematic viscosity of 1 mm²/s, and chemically non-aggressive liquids.
4.
TECHNICAL DATA AND RANGE OF USE
− Liquid temperature range:
− Supply voltage:
− Flow rate:
− Head up – Hmax (m):
− Degree of motor protection:
− Degree of terminal board protection:
− Thermal class:
− Absorbed power
− Maximum environment temperature:
− Storage temperature:
− Relative humidity of the air:
− Maximum working pressure:
− Motor construction: in conformity with standards CEI 2-3 pamphlet 1110
− Weight: see plate on package
− Dimensions: see fig. 1-2, page 95
− Line fuses AM class: indicative values (Amps)
KVC 3/3
KVC 3/4, KVC 3/5, KVC 6/3, KVC 6/4, KVC 10/2
KVC 6/5
KVC 3/7, KVC 10/3
KV 3/10, KV 3/12, KV 6/7, KV 6/9, KV 10/4
KV 32/34, KV 32/44, KV 32/54, KV 32/64, KV 32/74,
KV 32/84, KV 40/34, KV 40/44, KV 40/54, KV 50/34
KVE 3/10, KVE 3/12, KVE 6/7, KVE 6/9, KVE 10/4
KV 3/15, KV 6/11, KV 10/5
KV 32/94, KV 32/104, KV 32/114, KV 40/64, KV 40/74,
KV 50/44
KVE 3/15, KVE 6/11, KVE 10/5, KVE 10/6
KV 10/6
KV 3/18, KV 6/15, KV 10/8, KV 32/2
KV 32/124, KV 32/134, KV 32/144, KV 32/154, KV 40/84,
KV 40/94, KV 40/104, KV 50/54, KV 50/64
KVE 3/18, KVE 6/15, KVE 10/8
KV 32/3, KV 32/4, KV 40/2,
KV 40/114, KV 40/124, KV 40/134, KV 50/74, KV 50/84,
KV 50/94, KV 50/104, KV 50/114
KV 32/5, KV 40/3,
KV 50/124, KV 50/134, KV 50/144, KV 50/154
KV 32/6, KV 32/7, KV 32/8, KV 40/4, KV 40/5
KV 50/2, KV50/3
KV 40/6, KV 40/7, KV 40/8, KV 50/4, KV 50/5
KV 50/6
KV 50/7, KV 50/8
KV 50/9
All manuals and user guides at all-guides.com
ENGLISH
− KVC:
− KV:
− 50Hz: 1 x 220-240 V
from 1.8 to 45 m³/h (see fig. 5-6-7 page 97-98-99)
see fig. 5-6-7 page 97-98-99 - page 108
IP44 (For IP55 see plate on package)
IP55
F
see electric data plate
+40°C
-10°C to +40°C
max. 95%
KVC
KV-KVE 3 - 6 - 10
KV 32 - KV 40
KV 50
Model
from -10°C to +35°C
from -10°C to +50°C
from -15°C to +110°C
3 x 230-400 V up to 4 KW inclusive
3 x 400 V D over 4 KW
10 Bar (1000 KPa)
18 Bar (1800 KPa)
25 Bar (2500 KPa)
30 Bar (3000 KPa)
1 x 220-240V 50Hz
4
6
6
8
10
- -
12
- -
16
- -
- -
- -
- -
- -
- -
- -
- -
22
for
domestic
use
(safety
standards EN 60335-2-41)
for other uses
for the whole range
Line fuses
3 x 230V 50Hz
3 x 400V 50Hz
4
2
4
2
6
4
6
4
8
4
8
4
10
6
10
6
10
6
12
8
20
12
25
16
40
20
63
32
63
40
80
50
125
63