TABLE OF MODIFIABLE PARAMETERS
Code
Description
CHM1
Detergent concentration level 1
CHM2
Detergent concentration level 2
CHAS
Detergent empty alarm sound
Level 1 solution flow rate in relation to level 3 (flow rate as function of
P1/P3
speed)
Level 2 solution flow rate in relation to level 3 (flow rate as function of
P2/P3
speed)
Level 3 solution flow rate (flow rate as function of
P3
speed)
P4
Enablement of level 4 (3.8l/min in regardless of speed)
SPT
EcoFlex™ function timer
XPRES
Brush deck extra pressure enabling
FVMIN
Minimum forward speed
FVMAX
Maximum forward speed
RVMAX
Maximum reverse speed
BAT (**)
Installed battery type (see table)
TOFF
Automatic shut-off time
BRGH
Display contrast
VRID
Vacuum power in silent mode
DRPMA (*)
Reduced disc brush rpm activation threshold A
DRPMB (*)
Reduced disc brush rpm activation threshold B
CRPMA (*)
Reduced cylindrical brush rpm activation threshold A
CRPMB (*)
Reduced cylindrical brush rpm activation threshold B
RESET
Restore factory settings for all parameters
(*)
Increase the value of this parameter to reduce the brush motor speed in a wider range of applications and vice versa.
(**) As described in the Use/Operation chapter, set the machine and the on-board battery charger (where fitted) on the basis of the
type of battery to be installed by modifying the BAT parameter as shown in the following table:
SETTING
BATTERY TYPE
1
WET
2
GEL-AGM
3
GEL EXIDE
4
WET
5
GEL-AGM
6
GEL EXIDE
7
NEXSYS
8
LI-ION
NOTE
When using batteries with a capacity lower than 160Ah@5h (in case of doubt, refer to the battery documents), to avoid
battery overheating during charging procedure, use the REDUCED charging current with setting 4, 5 or 6 shown in the
table, according to the type of batteries installed.
SC650 66D - SC650 71D - SC650 85D - SC650 71C
CHARGING CURRENT
STANDARD
®
type
REDUCED (see note)
®
type
STANDARD
STANDARD
INSTRUCTIONS FOR USE
Minimum
0.25 % (1:400)
0.25 % (1:400)
OFF
0 %
0 %
SC650 66D
1 cl/m
SC650 71D
1 cl/m
SC650 85D
1 cl/m
SC650 71C
1 cl/m
OFF
0 (disabled)
SC650 66D
OFF
SC650 71D
OFF
SC650 85D
OFF
SC650 71C
OFF
0 %
10 %
10 %
0
0 (disabled)
5
1
5
5
5
5
OFF
55943387
ENGLISH
Values
Factory Setting
Maximum
0.25 % (1:400)
3 % (1:33)
0.80 % (1:125)
3 % (1:33)
ON
ON
25 %
100 %
50 %
100 %
5.1 cl/m
10 cl/m
5.5 cl/m
10 cl/m
6.5 cl/m
10 cl/m
5.5 cl/m
10 cl/m
OFF
ON
60 sec.
300 sec.
ON
ON
ON
ON
ON
ON
OFF
ON
15%
100 %
100%
100 %
50%
50 %
3
8
120 sec.
600 sec.
100
100
5
5
10
20
20
20
15
30
25
30
OFF
ON
27