Inbedrijfstelling
I
5
Complete parameterlijst
0 0
Naam
Par.
Omschakelbare par.
Parameterset 1/2
24_
Synchronous operation with catch up
240
Synchronous speed
241
Synchronous ramp
26_
Process controller parameters
260
Operating mode
261
Cycle time
262
Interruption
263
Factor K
p
264
Integrative time T
265
Derivative time T
266
Feedforward
27_
Proces controller input values
270
Setpoint source
271
Setpoint
272
IPOS setpoint address
273
Time constant
274
Scaling setpoint
275
Actual value source
276
IPOS actual value address
277
Actual scaling factor
278
Actual offset value
279
Atcual time constant
28_
Process controller limits
280
Minimum offset + actual value
281
Maximum offset + actual value
282
Minimum output PID controller
283
PID controller maximum output
284
Minimum output process controller
285
Maximum output process controller
3__
MOTOR PARAMETERS
30_ / 31_ Limits 1 / 2
\300 / 310 Start/stop speed 1 / 2
\301 / 311 Minimum speed 1 / 2
\302 / 312 Maximum speed 1 / 2
\303 / 313 Current limit 1 / 2
304
Torque limit
32_ / 33_ Motor compensation 1 / 2 (asynchronous)
\320 / 330 Automatic adjustment 1 / 2
321 / 331 Boost 1 / 2
322 / 332 IxR compensation 1
323 / 333 Premagnetizing time 1 / 2
324 / 334 Slip compensation 1 / 2
34_
Motor protection
340 / 342 Motor protection 1 / 2
341 / 343 Cooling type 1 / 2
344
Interval for motor protection
345 / 346 I
-U
monitoring 1/2
N
L
35_
Direction of rotation of the motor
350 / 351 Change direction of rotation 1 / 2
98
Instelbereik
Fabrieksinstelling
-6000 ... 1500 ... 6000 rpm
0 ... 2 ... 50 s
Controller off / Control / Step response
1 / 5 / 10 ms
No response / Move closer to setpoint
0 ... 1 ... 32767
0 ... 10 ... 65535 ms
n
0 ... 1 ... 30 ms
V
–32767 ... 0 ... 32767
Parameter / IPOS variable / Analog 1 / Analog 2
–32767 ... 0 ... 32767
0 ... 1023
0 ... 0.01 ... 2000 s
–32767 ... 1 ... 32,767
Analog 1 / Analog 2 / IPOS variable
0 ... 1023
–32767 ... 1 ... 32767
–32767 ... 0 ... 32767
0 ... 500 ms
–32767 ... 0 ... 32767
–32767 ... 10000 ... 32767
–32767 ... –1000 ... 32767
–32767 .... 10000 ... 32767
–32767 ... 0 ... 32767
–32767 ... 7500 ... 32767
0 ... 150 rpm
0 ... 15 ... 6100 rpm
0 ... 1500 ... 6100 rpm
0 ... 150 % (BG0: 0 ... 200 % I
0 ... 150 % (BG0: 0 ... 200 %)
Off
On
0 ... 100 %
0 ... 100 %
0 ... 2 s
0 ... 500 rpm
Off
On (asynchronous)
On (synchronous)
Fan cooled
Forced cooling
0,1 ... 4 ... 20 s
0,1 ... 500 A
Off
On
Technische handleiding – Applicatieregelaar MOVIDRIVE
Opmerking
)
nom
®
MDX60B/61B

Advertenties

loading

Deze handleiding is ook geschikt voor:

Movidrive mdx61b