E5
The fault code that appears is overcurrent protection or overload protection.
Troubleshooting method: Please turn off the power and reconnect.
E6
This fault is overload protection. Troubleshooting method: Please replace
the fuse on the
controller.
E7
E7 fault is due to the safety lock magnet not reaching the fixed area of the
safety switch, or the internal safety lock wiring falling off, troubleshooting
Method 1: If no safety lock magnet is placed in the safety lock area, please
place a safety lock configuration magnet,
Method 2: The position magnet has been placed in the safety lock area and
error E7 is reported. It is necessary to check whether the ribbon cable
connecting the safety lock module and the control board is in good contact.
If it falls off, please plug it in and troubleshoot the problem.
18